Logo BSU

Please use this identifier to cite or link to this item: https://elib.bsu.by/handle/123456789/95234
Title: Monte Carlo Simulation of the Electromagnetic Calorimeter Work by GEANT4
Authors: Salianka, R. V.
Keywords: ЭБ БГУ::ЕСТЕСТВЕННЫЕ И ТОЧНЫЕ НАУКИ::Физика
Issue Date: 2013
Publisher: Minsk : Education and Upbringing
Citation: Nonlinear Phenomena in Complex Systems. - 2013. - Vol. 16, N 3. - P. 309-313
Abstract: Experimental and theoretical studies of direct photon production in hadronic collisions essentially expand our insights about multiparticle production mechanisms. These photons are useful probes to investigate nuclear matter at all stages of the interaction. Soft photons(SP) play a particular role in these studies. A specific feature of the proposed photon detector is its capability to measure low energy deposit Ethresh ≤ 5 MeV. SP investigations are proposed to study at SVD-2 setup at U-70 accelerator, IHEP (Protvino, Russia), Nuclotron at JINR (Dubna, Russia) and at future collider NICA (JINR). For these purposes an electromagnetic calorimeter (ECal) is manufactured of BGO scintillators. The results of Monte Carlo simulation of ECal job for soft photon registration by using GEANT4 is presented.
URI: http://elib.bsu.by/handle/123456789/95234
ISSN: 1561-4085
Licence: info:eu-repo/semantics/restrictedAccess
Appears in Collections:2013. Volume 16. Number 3

Files in This Item:
File Description SizeFormat 
v16no3p309.pdf615,04 kBAdobe PDFView/Open
Show full item record Google Scholar