Logo BSU

Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот документ: https://elib.bsu.by/handle/123456789/342058
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorYe, S.-
dc.contributor.authorHancharou, D.-
dc.contributor.authorChen, H.-
dc.contributor.authorNedzvedz, A.-
dc.contributor.authorLv, H.-
dc.contributor.authorAblameyko, S.-
dc.date.accessioned2026-02-18T14:49:36Z-
dc.date.available2026-02-18T14:49:36Z-
dc.date.issued2020-
dc.identifier.citationPattern Recognition and Image Analysis. Advances in Mathematical Theory and Applications. 2020;Vol. 30(2): P. 237-246ru
dc.identifier.urihttps://elib.bsu.by/handle/123456789/342058-
dc.description.abstractThe vessel structures of the blood circulatory system are one of the most complex structures of the human body. Modern computed tomography techniques allow acquiring high resolution images, but at the same time, the number of artifacts in output images is quite high. They may affect diagnostic result and may obscure or simulate pathology. The idea of our method is to represent a 3D computed tomography image as a combination of vascular structure and background that has normal distribution in some neighborhood. Locally adaptive non-linear filters decrease global difference between bright and dark voxels, even if it pro- duces better local contrast. Luminosity and contrast are observed from image background and are used for normalization of the whole image. After making background normalization at each layer, we merge layers and reconstruct vessels structure. The proposed method has been tested on real cardiac CT images, the test results show that high quality 3D structures are reconstructed, without requiring a priori knowledge or user interaction. The tested dataset has been made publicly available. The proposed approach can be applied to denoising computed tomography images, enhancing of contrast in lesion areas without changing topology of initial vessel structures.ru
dc.language.isoenru
dc.publisherSpringer Natureru
dc.rightsinfo:eu-repo/semantics/openAccessru
dc.subjectЭБ БГУ::ЕСТЕСТВЕННЫЕ И ТОЧНЫЕ НАУКИ::Кибернетикаru
dc.titleExtraction of Vascular Structure in 3D Cardiac CT Images by Using Objectru
dc.typearticleru
dc.rights.licenseCC BY 4.0ru
dc.identifier.DOI10.1134/S1054661820020170-
dc.identifier.orcid0000-0001-9404-1206ru
Располагается в коллекциях:Кафедра веб-технологий и компьютерного моделирования (статьи)

Полный текст документа:
Файл Описание РазмерФормат 
S1054661820020170.pdf1,75 MBAdobe PDFОткрыть
Показать базовое описание документа Статистика Google Scholar



Все документы в Электронной библиотеке защищены авторским правом, все права сохранены.