Title: H+-селективный электрод для определения значений pH ниже нуля
Other Titles: H+-selective electrode for the determination of subzero pH values / A. V. Siamionau, V. V. Egorov
Authors: Семёнов, А. В.
Егоров, В. В.
Keywords: ЭБ БГУ::ЕСТЕСТВЕННЫЕ И ТОЧНЫЕ НАУКИ::Химия
Issue Date: 2023
Publisher: Минск : БГУ
Citation: Журнал Белорусского государственного университета. Химия = Journal of the Belarusian State University. Chemistry. – 2023. – № 1. – С. 37-49
Abstract: Рассмотрена теория функционирования H+-селективных электродов на основе нейтральных переносчиков аминного характера в кислой области, а также ключевые пути смещения верхнего предела обнаружения электрода в кислую область, такие как варьирование природы заместителей у атома азота в целях направленного уменьшения основности, рациональный выбор пластификатора и использование устойчивого в кислой среде ионообменника – тетракис(3,5-бис(трифторметил)фенил)бората калия. Изучено функционирование электрода на основе оригинального ионофора N-фенил-N-[(3,4,5-трис-додецилоксифенил)метил]этанамина для определения значений pH ниже нуля. Представлена методика определения pH верхнего предела обнаружения для электродов на основе низкоосновных ионофоров, заключающаяся в применении равнопереносящих растворов смешанного электролита, что дает возможность элиминировать вклад диффузионного потенциала. Предложено использование в качестве электрода сравнения серебряной проволоки, покрытой электроосажденным хлоридом серебра, что позволяет повысить чувствительность измерений в растворах соляной кислоты. Показана возможность применения разработанного H+-селективного электрода для определения pH в солянокислых растворах вплоть до значения –1,5, соответствующего 4 моль/л раствору.
Abstract (in another language): he theory of functioning in acidic region of H+-selective electrodes based on amine-type neutral carriers, as well as general ways to shift the upper detection limit to acidic region, such as varying the nature of nitrogen atom substituents to target lower basicity, optimal plasticiser choice and the usage of the ion exchanger that is stable in acidic solutions, namely, potassium tetrakis(3,5-bis(trifluoromethyl)phenyl)borate are considered. The electrode based on original ionophore that is N-phenyl-N-[(3,4,5-tris-dodecyloxyphenyl)methyl]ethanamine functioning to determine subzero pH values was studied. A method to determine pH of the upper detection limit for electrodes based on ionophores with low basicity is suggested. The method is based on usage of equally transferring solutions of mixed electrolyte that eliminates diffusion potential. The usage of silver wire covered with electrodeposited silver chloride as a reference electrode that increases the measurements sensitivity in hydrochloric acid solutions is considered. It was shown that the H+-selective electrode elaborated is suitable for pH determination in hydrochloric acid solutions down to –1.5 that corresponds to 4 mol/L solution.
Description: Авторы выражают благодарность Е. Б. Окаеву за синтез веществ, использованных при выполнении экспериментальной части работы. = The authors thank Ya. B. Akayeu for the synthesis of substances used for the experimental part of the present work.
URI: https://elib.bsu.by/handle/123456789/298065
ISSN: 2520-257X
DOI: 10.33581/2520-257X-2023-1-37-49
Sponsorship: Работа выполнена в рамках государственной программы научных исследований «Химические процессы, реагенты и технологии, биорегуляторы и биооргхимия» (No 2.1.01.02/2). = This work was supported by the governmental programme of scientific research «Chemical proces ses, reagents and technologies, bioregulators and bioorgchemistry» (project No. 2.1.01.02/2).