Please use this identifier to cite or link to this item:
https://elib.bsu.by/handle/123456789/233866
Title: | Легирование кремния малого диаметра в вертикальном канале 230 мм реактора ИРТ-Т |
Other Titles: | Small Diameter Silicon Doping in Vertical Channel 230 mm of IRT-T Reactor / N.V. Smolnikov, I.I. Lebedev, M.N. Anikin, A.G. Naymushin, V.A. Varlachev |
Authors: | Смольников, Н. В. Лебедев, И. И. Аникин, М. Н. Наймушин, А. Г. Варлачев, В. А. |
Keywords: | ЭБ БГУ::ЕСТЕСТВЕННЫЕ И ТОЧНЫЕ НАУКИ::Физика |
Issue Date: | 2019 |
Publisher: | Минск : БГУ |
Citation: | Взаимодействие излучений с твердым телом = Interaction of Radiation with Solids : материалы 13-й Междунар. конф., Минск, Беларусь, 30 сент. – 3 окт. 2019 г. / редкол.: В. В. Углов (отв. ред.) [и др.]. – Минск : БГУ, 2019. – С. 552-554. |
Abstract: | В работе рассматривается проблема одновременного легирования слитков кремния малого диаметра в большом экспериментальном канале реактора ИРТ-Т. Показана принципиальная возможность создания контейнера для легирования слитков кремния. Для достижения необходимых параметров радиального и аксиального коэффициента неравномерности распределения легирующей примеси проведен нейтронно-физический расчет с целью определения оптимального материального состава фильтра тепловых нейтронов. Кроме того, в работе были показаны способы размещения фильтра тепловых нейтронов в объеме контейнера. Показаны методы выравнивания профиля распределения легирующей примеси по объему слитка. Расчеты показали, что использование фильтров в квазистационарном поле облучения позволяют достичь разброса содержания легирующих примесей по высоте слитка менее 5%. Произведен теплофизический расчет процесса облучения слитков кремния малого диаметра и доказана безопасность эксплуатации установки. |
Abstract (in another language): | The paper deals with the problem of simultaneous doping of small-diameter silicon ingots in a large experimental channel. The principal possibility of creating a container for the doping of silicon ingots is shown. To achieve the required parameters of the radial and axial coefficient of uneven distribution of the doping impurity, a neutron-physical calculation was performed to determine the optimal material composition of the thermal neutron filter. It is shown that for as a filler material it is possible to use reactor graphite or aviation aluminum alloys. In addition, the work showed methods for placing a thermal neutron filter in the container volume. The methods of leveling the distribution profile of the dopant by ingot volume are shown. Calculations have shown that the use of filters in a quasistationary irradiation field makes it possible to achieve a variation in the content of dopants in an ingot height less than 5%. The work also shows two methods of rotating the samples to align the radial non-uniformity. The thermophysical calculation of the process of irradiation of silicon ingots of small diameter was made and the safety of the installation was proved. The maximum temperature of the wall water is no more than 53 ° C. The total energy release of the installation is about 60 kW. |
Description: | Секция 6. Современное оборудование и технологии = Section 6. Advances in Equipment and Technologies |
URI: | http://elib.bsu.by/handle/123456789/233866 |
ISSN: | 2663-9939 |
Appears in Collections: | 2019. Взаимодействие излучений с твердым телом = Interaction of Radiation with Solids |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
552-554.pdf | 450,46 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.