Заглавие документа: | Glass capillary X-ray lens: fabrication technique and ray tracing calculations |
Авторы: | Dudchik, Yu. I. Kolchevsky, N. N. Komarov, F. F. Kohmura, Y. Awaji, M. Suzuki, Y. Ishikava, T. |
Тема: | ЭБ БГУ::ЕСТЕСТВЕННЫЕ И ТОЧНЫЕ НАУКИ::Физика |
Дата публикации: | 2000 |
Библиографическое описание источника: | Nuclear Instruments and Methods in Physics Research. Section A. - 2000. - № 454. - 512-519. |
Аннотация: | A new method for producing a compound refractive X-ray lens is described. The lens is designed as glass capillary "lled by a set of concave individual lenses. The method is appropriate for the preparation of 10}1000 spherical lenses in a glass capillary with a diameter of 0.1}1 mm. Lens aberrations are considered and simple formulas for spot size are derived. Ray-tracing simulations on the focusing experiments using 18 keV X-rays are reported. ( 2000 Elsevier Science B.V. All rights reserved. |
URI документа: | http://elib.bsu.by/handle/123456789/19345 |