Logo BSU

Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот документ: https://elib.bsu.by/handle/123456789/344314
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorCharapitsa, S.-
dc.contributor.authorSytova, S.-
dc.contributor.authorKavalenka, A.-
dc.contributor.authorSabalenka, L.-
dc.contributor.authorZayats, M.-
dc.contributor.authorEgorov, V.-
dc.contributor.authorLeschev, S.-
dc.contributor.authorMelsitova, I.-
dc.contributor.authorVetokhin, S.-
dc.contributor.authorZayats, N.-
dc.date.accessioned2026-03-23T08:09:40Z-
dc.date.available2026-03-23T08:09:40Z-
dc.date.issued2022-
dc.identifier.citationJournal of Food Composition and Analysis.2022; Vol. 114: P. 104772ru
dc.identifier.urihttps://elib.bsu.by/handle/123456789/344314-
dc.description.abstractA gas chromatography flame ionization detector (GC-FID) method based on the use of ethanol as an internal standard was developed and in-house validated for the direct determination of methanol in ethanol containing products (alcoholic beverages and rectified ethyl alcohol) with ethanol concentrations from 6.5 % to 96.6 % by volume. Validation of the method was performed in terms of linearity, limit of detection (LOD), limit of quantification (LOQ), recovery, repeatability, intermediate precision, trueness, uncertainty and matrix effect. The method showed satisfactory results, considering the parameters of linearity (R2 ≥ 0.999), LOQ and LOD (0.5 and 1.5 mg/L, correspondingly), recovery (95–105 %), standard deviation of repeatability (2.6 %), standard deviation of intermediate precision (3.4 %) and relative expanded uncertainty (with coverage factor k = 2 and confidence level P = 95 %) of method (7.4 %). The developed method has been applied to 23 samples of different types of alcoholic beverages (brandy, gin, rum, calvados, whiskey, bourbon, vermouth, slivovice, tsikoudia, sake, tequila, grappa, mulled wine, strong drink, grain spirit, nalewka, cocktail, krupnik, bitter and sweet tinctures, sweet, herbal and egg liquors). The absence of matrix effect associated with ethanol volume concentration and presence of non-volatile compounds in studied alcoholic beverages was proven.ru
dc.language.isoenru
dc.publisherAcademic Pressru
dc.rightsinfo:eu-repo/semantics/openAccessru
dc.subjectЭБ БГУ::ЕСТЕСТВЕННЫЕ И ТОЧНЫЕ НАУКИ::Химияru
dc.subjectЭБ БГУ::ТЕХНИЧЕСКИЕ И ПРИКЛАДНЫЕ НАУКИ. ОТРАСЛИ ЭКОНОМИКИ::Пищевая промышленностьru
dc.titleIntelligent use of ethanol for the direct quantitative determination of methanol in alcoholic beveragesru
dc.typeconference paperru
dc.rights.licenseCC BY 4.0ru
dc.identifier.DOI10.1016/j.jfca.2022.104772-
dc.identifier.orcid0000-0001-9657-1948ru
dc.identifier.orcid0000-0002-2476-9979ru
dc.identifier.orcid0000-0002-0320-2092ru
dc.identifier.orcid0000-0001-5066-7194ru
dc.identifier.orcid0000-0002-8400-6359ru
dc.identifier.orcid0000-0001-5378-1718ru
dc.identifier.orcid0000-0003-0930-8530ru
Располагается в коллекциях:Статьи НИУ «Институт ядерных проблем»

Полный текст документа:
Файл Описание РазмерФормат 
bioconf_oiv2023_04001-1.pdf1,27 MBAdobe PDFОткрыть
Показать базовое описание документа Статистика Google Scholar



Все документы в Электронной библиотеке защищены авторским правом, все права сохранены.