Logo BSU

Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот документ: https://elib.bsu.by/handle/123456789/342246
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorKoktysh, I.V.-
dc.contributor.authorMelnikova, Y.I.-
dc.contributor.authorKulakovich, O.S.-
dc.contributor.authorRamanenka, A.A.-
dc.contributor.authorVaschenko, S.V.-
dc.contributor.authorMuravitskaya, A.O.-
dc.contributor.authorGaponenko, S.V.-
dc.contributor.authorMaskevich, S.A.-
dc.date.accessioned2026-02-20T12:31:01Z-
dc.date.available2026-02-20T12:31:01Z-
dc.date.issued2020-
dc.identifier.citationJournal of Applied Spectroscopy.2020; 87(5): P. 870-876ru
dc.identifier.urihttps://elib.bsu.by/handle/123456789/342246-
dc.description.abstractWe consider the possibilities of applying the plasmon-enhanced fluorescence of monoclonal antibodies labelled with fluorescein isothiocyanate (FITC) to the prostate-specific antigen (PSA) for increasing the immunofluorescence analysis sensitivity. An immunochemical test system featuring two center binding using a pair of noncompeting monoclonal antibodies in combination with silver plasmon nanoparticles was used for the first time for determining the PSA concentration. The advantages over the standard PSA immunofluorescence assay are as follows. The intensity of the recorded fluorescent signal is enhanced by 2.3–3.2 times in the presence of silver nanoparticles in comparison with the signal of the test system on the intact surface of a polystyrene plate. The signal-to-noise ratio is increased by up to two times. In addition to the plasmon-enhanced fluorescence, the effect of an intermediate polyelectrolyte layer for enhancement of the adsorption capacity of the primary PSA antibodies is shown, which, in turn, affects the fluorescence signal intensity. Growth of the plasmon fluorescence enhancement factor with increasing concentration of the labelled antibodies indicates suppression of the self-quenching of the fluorescent labels by metal nanoparticles.ru
dc.language.isoenru
dc.publisherSpringer Natureru
dc.rightsinfo:eu-repo/semantics/openAccessru
dc.subjectЭБ БГУ::ЕСТЕСТВЕННЫЕ И ТОЧНЫЕ НАУКИ::Физикаru
dc.subjectЭБ БГУ::ТЕХНИЧЕСКИЕ И ПРИКЛАДНЫЕ НАУКИ. ОТРАСЛИ ЭКОНОМИКИ::Медицина и здравоохранениеru
dc.subjectЭБ БГУ::ЕСТЕСТВЕННЫЕ И ТОЧНЫЕ НАУКИ::Биологияru
dc.titleHighly Sensitive Immunofluorescence Assay of Prostate-Specific Antigen Using Silver Nanoparticlesru
dc.typearticleru
dc.rights.licenseCC BY 4.0ru
dc.identifier.DOI10.1007/s10812-020-01083-2-
dc.identifier.orcid0000-0001-7644-4968ru
Располагается в коллекциях:Научные публикации, проиндексированные в SCOPUS и WoS

Полный текст документа:
Файл Описание РазмерФормат 
s10812-020-01083-2.pdf1,49 MBAdobe PDFОткрыть
Показать базовое описание документа Статистика Google Scholar



Все документы в Электронной библиотеке защищены авторским правом, все права сохранены.