Logo BSU

Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот документ: https://elib.bsu.by/handle/123456789/340502
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorСиницына, М. М.
dc.contributor.authorАсадчиков, В. Е.
dc.contributor.authorФедоров, В. А.
dc.contributor.authorБузмаков, А. В.
dc.contributor.authorРощин, Б. С.
dc.contributor.authorДьячкова, И. Г.
dc.contributor.authorКузин, С. В.
dc.date.accessioned2026-01-22T14:39:51Z-
dc.date.available2026-01-22T14:39:51Z-
dc.date.issued2025
dc.identifier.citationВзаимодействие излучений с твердым телом : материалы 16-й Междунар. конф., Минск, Беларусь, 22-25 сент. 2025 г. / Белорус. гос. ун-т ; редкол.: В. В. Углов (гл. ред.) [и др.]. – Минск : БГУ, 2025. – С. 514-517.
dc.identifier.issn2663-9939 (print)
dc.identifier.issn2706-9060 (online)
dc.identifier.urihttps://elib.bsu.by/handle/123456789/340502-
dc.descriptionСекция 5. Методы, оборудование, плазменные и радиационные технологии = Section 5. Methods, Equipment, Plasma and Radiation Technologies
dc.description.abstractРазработка высокоэффективных рентгеновских детекторов с микронным пространственным разрешением является актуальной задачей, особенно в условиях ограниченного доступа к импортным компонентам. В работе представлены результаты тестирования и оптимизации сцинтилляторов для использования в составе детектора для лабораторного микротомографа с CMOS-матрицей и оптическим увеличением. Особое внимание уделено сравнению характеристик монокристаллических сцинтилляторов на основе YAG:(Ce,Tb) с коммерчески доступными экранами типа DRZ-High. Показано, что даже при толщине до 475 мкм сцинтилляторы на основе YAG:(Ce,Tb) позволяют регистрировать объекты с размером структур до 6 мкм. Проведен анализ факторов, влияющих на выбор сцинтиллятора, включая световой выход, толщину, спектральное соответствие чувствительности CMOS-матрицы и качество обработки. Полученные результаты создают предпосылки для разработки отечественных детекторов с высоким разрешением и в то же время указывают на необходимость доработки технологии изготовления сцинтилляторов
dc.description.sponsorshipРабота проведена в рамках выполнения государственного задания Национального исследовательского центра «Курчатовский институт».
dc.language.isoru
dc.publisherМинск : БГУ
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectЭБ БГУ::ЕСТЕСТВЕННЫЕ И ТОЧНЫЕ НАУКИ::Физика
dc.titleИсследование эффективности различных сцинтилляционных экранов в составе детектора для высокоразрешающей рентгеновской микротомографии
dc.title.alternativeStudy of the Efficiency of Different Scintillation Screens in the Detector for High-Resolution X-Ray Microtomography / Sinitsyna Maria, Asadchikov Victor, Fedorov Vladimir, Buzmakov Alexey, Roshchin Boris, Dyachkova Irina, Kuzin Sergey
dc.typeconference paper
dc.description.alternativeDevelopment of high-performance X-ray detectors with micron spatial resolution is an urgent task, especially in conditions of limited access to imported components. In this work we tested a detector designed for high-resolution X-ray microtomography. The results of testing and optimization of scintillators for use in the detector for laboratory microtomograph with CMOS-matrix having the format of 2064x1544 pixels with pixel size of 3.45x3.45 microns and optical magnification of about 3 times are presented. As a result of selection and experimental testing of scintillators the optimal material was chosen - YAG (yttrium-aluminum garnet) activated by cerium and terbium ions. Crystals for scintillators were grown by Bagdasarov method. The conducted studies confirmed their suitability: an image with a resolution of about six micrometers was obtained using optical magnification (for scintillators of different thicknesses from 100 to 475 µm), which indicates the high efficiency of the proposed approach. Special attention is paid to the comparison of the characteristics of single-crystal scintillators based on YAG:(Ce,Tb) with a commercially available DRZ-High type screen made on the basis of gadollinium oxysulfide deposited on a polymer base and having a phosphor thickness of 320 µm. The surface quality of DRZ-High was not good enough for high-resolution imaging tasks. The surface analysis showed a pronounced roughness, reaching the visually distinguishable structure, which leads to significant optical distortions and blurring of the image. However, even for the created scintillators based on YAG:(Ce,Tb) the problems related to the inhomogeneity of dopant distribution were revealed. This inhomogeneity is manifested in the form of local zones of increased brightness, which can be caused by the concentration of luminescent centers. An additional difficulty is introduced by poor surface quality. Elimination of these defects requires further optimization of the grinding and polishing process. The obtained results demonstrate the potential for creation of domestic detectors with high resolution and emphasize the need for further improvement of scintillator manufacturing technology