Logo BSU

Please use this identifier to cite or link to this item: https://elib.bsu.by/handle/123456789/324832
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGaikovich, K.P.-
dc.contributor.authorMaksimovitch, Ye.S.-
dc.contributor.authorBadeev, V.A.-
dc.contributor.authorBadeev, L.A.-
dc.contributor.authorBockeria, L.A.-
dc.contributor.authorDjitava, T.G.-
dc.contributor.authorKakuchaya, T.T.-
dc.contributor.authorKuular, A.M.-
dc.date.accessioned2025-01-22T13:24:58Z-
dc.date.available2025-01-22T13:24:58Z-
dc.date.issued2023-
dc.identifier.citationDiagnostics 2023; 13(6): 1051ru
dc.identifier.urihttps://elib.bsu.by/handle/123456789/324832-
dc.description.abstractThe developed near-field microwave diagnostics of dynamical lung tomography provide information about variations of air and blood content depth structure in the processes of breathing and heart beating that are unattainable for other available methods. The method of dynamical pulse 1D tomography (profiling) is based on solving the corresponding nonlinear ill-posed inverse problem in the extremely complicated case of the strongly absorbing frequency-dispersive layered medium with the dual regularization method—a new Lagrange approach in the theory of ill-posed problems. This method has been realized experimentally by data of bistatic measurements with two electrically small bow-tie antennas that provide a subwavelength resolution. The proposed methods of 3D lung tomography based on the multisensory pulse, multifrequency, or multi-base measurements are based on solving the corresponding integral equations in the Born approximation. The experimental 3D tomography of lung air content was obtained by the results of the multiple 1D pulse profiling by pulse measurements in several grid points over the planar square region of the thorax. Additionally, the possible applicability of multifrequency measurements of scattered harmonic signals in the monitoring of lungs was demonstrated by four-frequency measurements in the process of breathing. The results demonstrated the feasibility of the proposed control in the diagnosis of some lung diseases.ru
dc.language.isoenru
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)ru
dc.rightsinfo:eu-repo/semantics/openAccessru
dc.subjectЭБ БГУ::ТЕХНИЧЕСКИЕ И ПРИКЛАДНЫЕ НАУКИ. ОТРАСЛИ ЭКОНОМИКИ::Медицина и здравоохранениеru
dc.subjectЭБ БГУ::ЕСТЕСТВЕННЫЕ И ТОЧНЫЕ НАУКИ::Физикаru
dc.titleMicrowave Near-Field Dynamical Tomography of Thorax at Pulmonary and Cardiovascular Activityru
dc.typearticleru
dc.rights.licenseCC BY 4.0ru
dc.identifier.DOI10.3390/diagnostics13061051-
Appears in Collections:Кафедра квантовой радиофизики и оптоэлектроники. Статьи

Files in This Item:
File Description SizeFormat 
sndte4e3.pdf1,27 MBAdobe PDFView/Open
Show simple item record Google Scholar



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.