Logo BSU

Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот документ: https://elib.bsu.by/handle/123456789/323066
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorKorban, A.-
dc.contributor.authorČabala, R.-
dc.contributor.authorEgorov, V.-
dc.contributor.authorBosáková, Z.-
dc.date.accessioned2024-12-13T11:44:46Z-
dc.date.available2024-12-13T11:44:46Z-
dc.date.issued2024-
dc.identifier.citationJournal of Separation Science 2024; 47(1): 2300492ru
dc.identifier.urihttps://elib.bsu.by/handle/123456789/323066-
dc.description.abstractThis study compares the variability of relative response factors (RRFs) using Taguchi's multifactorial analysis for two internal standard (IS) methods in gas chromatography (GC) for quality control of alcoholic products. Methods where either ethanol or pentan-1-ol was used as an IS were compared. For ten volatile substances prescribed by legislation, the RRFs of both methods were compared under 27 different experimental conditions. The influence of parameters (control factors) such as ethanol content in the matrix, analyte concentration, injected volume, injector temperature, split ratio, and flame ionization detector temperature was evaluated. The selected control factors had values at one of the three levels to cover the commonly used ranges of their settings in the measuring system and to characterize the majority of alcoholic products commonly analyzed in practice. The obtained results showed that the biggest differences in the variability of the results between the two methods were found for the most strictly controlled substances in alcoholic products, acetaldehyde, and methanol, where the application of ethanol as an IS provides clearly better results. For both methods, the way control factors affect the repeatability of GC measurements expressed in the form of relative deviation was also evaluated.ru
dc.description.sponsorshipThis work was not supported by any project or agency.ru
dc.language.isoenru
dc.publisherJohn Wiley and Sons Incru
dc.rightsinfo:eu-repo/semantics/openAccessru
dc.subjectЭБ БГУ::ЕСТЕСТВЕННЫЕ И ТОЧНЫЕ НАУКИ::Химияru
dc.titleVariability of internal standard method calibration factors estimated with a multifactorial Taguchi experiment in the analysis of alcoholic products by gas chromatography with flame ionization detectionru
dc.typearticleru
dc.rights.licenseCC BY 4.0ru
dc.identifier.DOI10.1002/jssc.202300492-
dc.identifier.scopus85178474115-
Располагается в коллекциях:Статьи химического факультета

Полный текст документа:
Файл Описание РазмерФормат 
J of Separation Science - 2023 - Korban - Variability of internal standard method calibration factors estimated with a.pdf2,59 MBAdobe PDFОткрыть
Показать базовое описание документа Статистика Google Scholar



Все документы в Электронной библиотеке защищены авторским правом, все права сохранены.